Thursday, June 10, 2010

Smardt Displaying at 28th West Coast EMC Show, June 15-16

Smardt is bringing their high-efficiency chillers to Seattle to show in the upcoming 28th West Coast Energy Management Congress Expo. Come see the industry leading oil-free compressor chillers and chiller controls systems first hand!



Exposition Hours:

Tuesday, June 15, 2010: 10:00 AM to 4:00 PM
Wednesday, June 16, 2010: 10:00 AM to 2:00 PM

Free tickets to the expo are available here.

The show will highlight energy efficiency products and programs and is supported by local utilities, industry organizations and local industry. It should be a very informative and exciting show, and it is conveniently located at the Washington State Convention and Trade Center in downtown Seattle.



See you there!

Friday, January 18, 2008

The Dark Side of Chiller oil

Most compressorized systems operate with oil mixed in with the refrigerant. This oil is required for lubrication of the shaft bearing and, in positive displacement compressors like scrolls or screws, it actually provides the seal that is necessary to effect the compression of the refrigerant. The oil is miscible with the refrigerant, and travels with it throughout the system to provide lubrication and compression sealing. That means the oil is everywhere the refrigerant is—Which can lead to several operation problems that need to be addressed in the design and operation of the system.

The first issue is oil transport. The oil travels with the refrigerant whenever the velocity of the refrigerant is high enough to carry the oil with it. This means that the system must be designed to ensure adequate velocities are met at all times. The biggest obstacle to refrigerant flow occurs, however, at the expansion device between the condenser and the evaporator. This is by design a big restriction on refrigerant flow—the greater the restriction, the greater the pressure drop across it and therefore the larger the temperature difference between condenser and evaporator. Its function is similar to that of a flow restrictor in a shower head or an orifice plate in a commercial piping system. Therefore, in order to ensure an adequate flow rate for oil transport between the condenser and evaporator, the pressure between these components must be kept above a minimum. If the pressure difference falls below this minimum, oil starts stacking up in the condenser and the machine will trip out on low oil pressure.

While there are methods that can be used to minimize this problem, such as oil pumps and eductors that siphon the accumulated oil out of the condenser, these are usually only provided on larger tonnage centrifugal machines, and even then there is a practical limit to the operating environment the compressor is designed for. In practice, head pressure control is used where low condensing temperatures are expected, such as fan cycling on air-cooled condensers or bypass lines on water cooled compressors. And even then, oil transport problems are a major cause of chiller downtime, especially in cool climates.

These head-pressure control mechanisms ensure a minimum condensing pressure to assure oil transport—which is good, because this ensures trouble-free operation. But it does this at the cost of energy efficiency.

See, a compressor is very similar to a pump. The total mass flow of refrigerant can be thought of as analogous to the flow rate of the pump and the pressure difference between the evaporator and condenser is analogous to the static head of the pump. In order to reduce energy use on a pump, you can either reduce the flow rate through the pump, or you can reduce the static head. In a chiller system you have the same options, but remember that the refrigerant mass flow rate is what determines the cooling capacity of the chiller. If you want to reduce energy use, but still provide the same cooling capacity, your only option is to reduce condenser pressure. One of the great advantages of using the ambient air as a heat sink is that for over 99% of the year, you have access to air temperatures (wet bulb or dry bulb, depending on the heat rejection of the system) below your design condition. This is why part load ratings on chillers are so much better than peak load ratings.


Head pressure controls, however, artificially limit how low this head pressure can go. Just when you are really getting efficient, the system kicks in a mechanism to keep your system from getting any more efficient! Without the need to maintain oil flow, a compressor can take full advantage of the available head pressure relief and operate extremely efficiently.

The second major issue with oil in your system is that it actually inhibits heat transfer, reducing the overall efficiency of the refrigeration system. In fact, a nominal 3.5% charge of oil in a chiller system equates to about an 8% loss of efficiency from this insulating effect (from ASHRAE 601).


And this only gets worse with time. An ARI study found that this insulating effect increases for the first 5-6 years of operation reducing chiller efficiency by about 20% due to oil fouling of the heat transfer surfaces in the chiller.

These numbers assume a constant oil charge—which is a big assumption. In practice, chiller oil charges often exceed the recommended oil charge by very significant amounts—since a common method of correcting a ‘low oil pressure’ alarm is to add more oil—despite the fact that the usual cause of this alarm is the stacking of refrigerant in the condenser, not any loss of oil in the machine. The same ASHRAE study above sampled many machines in the field and found that the average charge of oil was nearly 13% which equates to a total efficiency loss of 21%!

The last major issue with oil in the compressor is the chance of motor burnout. If a refrigerant system experiences a small leak in a low pressure location, moisture and air can enter the refrigerant system. Enough moist air can react with the refrigerant and oil to form hydrochloric and hydrofluoric acids which then travel through the system to the motor windings and eat away the insulation, eventually causing massive arcing and a catastrophic failure of the compressor motor. This acidic residue will be deposited throughout they system, requiring extensive flushing of the chiller shells before the system can safely be brought back on line. This is not only very expensive, but amounts to a very long downtime in what may be a critical building component.


Developed in Australia in the mid-90’s, the Turbocor™ compressor was born out of a desire to avoid the energy penalty and maintenance headaches associated with oil in the refrigerant circuit of traditional compressorized cooling systems.


These centrifugal compressors utilize a unique magnetic bearing to completely avoid the need for oil in the refrigerant system. These systems require very little maintenance and provide excellent efficiency both initially and many years down the road.

Smardt manufacturers water-cooled and air-cooled chillers exclusively utilizing these innovative compressors. These chillers avoid all of the drawbacks of oil, and eliminate much of the cost of ownership that is commonly associated with chiller systems. Since the bearings do not wear, traditional scheduled stop-major chiller teardowns are unnecessary, and all of the downtime and cost associated with oil (around 50% of the maintenance cost on these systems) are avoided. Smardt chillers provide an owner with excellent efficiency, reliability and economy.

Sunday, January 13, 2008

Aaon Goes 'Outside the Box' in HPAC article

Aaon makes some news in the HPAC Magazine article 'Outside-the-Box' Thinking Produces Outside-the-Building Mechanical Room published in the December 2008 issue.


The article discusses the conversion of an old Apollo Mission facility into a modern printing facility. Great economies were realized by using Aaon LL chillers and air handlers. The LL chillers can be provided with pumps, boilers and accessories to create a full 'mechanical room in a box' that can be shipped to the site, pre-designed and pre-piped. As the article describes:


Recognizing that a different type of solution was called for, Ecogenia, a Montreal-based distributor of HVAC products and controls, specified two 335-ton LL Series chillers from AAON Inc. The LL Series integrates mechanical-room components into a single packaged outdoor unit that includes a heat exchanger, a pumping package, boilers, expansion tanks, controls, and an air-cooled or a high-efficiency evaporatively cooled condenser section. A cooling tower is not required.


Aaon LL chillers can be laid out using the Ecat32 software in just a few minutes, and the installation of an entire mechanical room is a easy as a crane pick and utility connection. This may be just the solution for your next project!

Read more about LL chillers here (pdf).

Saturday, October 27, 2007

Introduction to Modular Chillers


Modular chillers are a product innovation that has recently gained wide acceptance in the HVAC industry. But since they cost more than standard chillers on a per-ton basis, it might seem a unlikely that this equipment would be a very popular cooling solution. However, modular chillers offer advantages that are not available with standard chiller equipment.

These advantages can be summarized in a few points:
  • Ease of Installation
  • Compact footprint
  • Redundancy


Ease of Installation

Modular chillers were originally developed as replacement chillers for existing building chiller plants. Many chillers are located in the bowels of the buildings they serve. It is often far easier to remove the existing equipment in pieces than to find a rigging path suitable to take it out of the building in one piece. Of course, this only helps if it is also possible to move the new chilling capacity into the chiller room in pieces!

Modular chillers were designed to fit through standard doors and to have a small turning radius to negotiate internal corridors without requiring demolition of existing walls.





Additionally, since these modules are light enough to ride in a freight elevator, it is usually possible to avoid crane costs for the installation project. Further cost savings are realized once the modules are in the room. Since each module has very low refrigerant volumes, the retrofit usually does not trigger codes requiring refrigerant monitoring or emergency ventilation.

Compact Footprint

In order to fit through doors and down corridors, modular chillers are designed to be extremely compact. They use highly efficient brazed plate heat exchangers to minimize their size as much as possible:



The result is a chiller plant with the smallest footprint per ton of any current option available--even if you are installing the modules in a new project instead of a retrofit.


330 ton chiller plant comparison (click for larger image)


Redundancy

With multiple, independent modules, modular chillers provide unmatched redundancy. If a single circuit is down there are always multiple other circuits operating. And providing N+1 redundancy to a modular chiller plant is far less expensive in first costs and mechanical room space than for any other chiller type. This inherent modularity allows fantastic turndown capabilities, and the part-load efficiency of a modular chiller plant is comparable with that of a large constant speed centrifugal or screw chiller.

ClimaCool Advantages

ClimaCool modular chillers were designed to take full advantage of the modular chiller design. For example, some manufacturers design their chillers for modular installation, but not modular operation. These chillers are designed with an electrical bus bar system to power all of the modules from a single power source. This may mean a slight savings at installation, but significantly degrades the redundancy advantage of this type of chiller. With a bus bar system if one chiller needs to be worked on, the entire array needs to be powered off.

ClimaCool avoids this disadvantage by powering each module independently of all the others:



Similarly, ClimaCool offers full redundancy on the water side, too, by providing isolation valves for the heat exchangers as a standard feature. Some manufacturers offer these valves as a first-cost add and they may significantly affect the chiller's footprint dimensions if added. Providing these valves as standard provides for yet another ClimaCool advantage: Easy conversion to a variable primary flow system! Modular chillers have a tight flow envelope on the brazed plate heat exchangers--each heat exchanger should essentially be considered a constant-flow device. By providing electric actuators controlled by the chiller controller on these isolation valves, the modular chiller plant can easily adjust for variable primary flow.

Another way in which ClimaCool offers advantages over other modular designs is in heat exchanger protection. Brazed-plate heat exchangers are highly efficient and very compact, but they demand very clean water to prevent clogging. All manufacturers of modular chiller equipment require straining of the system water before it enters the exchanger. Some manufacturers provide large-mesh strainers that are mounted in the headers serving the heat exchangers at each module. This approach requires an annual back-flush of the heat exchangers to clean out the debris that inevitably passes through the mesh. It also discourages proper maintenance, since the strainers are hard to get to and are therefore often ignored until clogging causes flow problems. ClimaCool takes a different approach, using small-mesh basket-type strainers outside of the headers to prevent heat exchanger fouling. This eliminates the need for annual back-flushing, and greatly eases maintenance. They also offer a deluxe 80-mesh high-capacity strainer option for especially dirty water or for systems where maintenance man-hours are limited:


Additionally, ClimaCool provides, as standard, convenient back-flush hose-bibs to allow this sort of maintenance as needed without requiring disassembly of the chiller header or taking the other modules off-line.



And, of course, ClimaCool offers chillers that comfortably exceed minimum energy code requirments:



Efficiency, redundancy, compact size and ease of installation: All reasons to consider ClimaCool modular chillers for your next chiller project.